ACME
PROCUREMENT INTELLIGENCE
DashboardD-TX-2026-0047Phase 6 · Evaluation

IT & Communications — Nexara

Generated by Aria · 4 checklist items · pack reviewed by Eng. Saif Al-Dhaheri

Evaluation pack

IT & Communications

SCADA / DCS compatibility, IEC 61850 protocols, firmware, cybersecurity.

NP

Vendor
Nexara Power Systems
Tender ref.
D-TX-2026-0047
Generated
30 Apr 2026, 11:23 GST
Reviewer
Eng. Saif Al-Dhaheri
AI model
Schema
P6 v1.4 — IEC 60076 transformer pack
Overall recommendation · Recommended

Online DGA / IEC 61850 reporting interface declared. Tap changer monitoring via fibre-optic where offered. SCADA-side validation against DNP3 and IEC 61850 Edition 2.1 confirmed.

IT & Communications requirements

(IEC 61850 · SCADA · Cybersecurity · Firmware)2/6 requirements met
RefRequirementStatusNoteRef
IT-1IEC 61850 Ed. 2 — GOOSE messaging & Sampled Values
Meets
IEC 61850 Ed. 2 GOOSE messaging confirmed; SFP fibre port on protection kiosk.
IT-2Fibre optic interface (IEC 60044-8 / 100Base-FX SFP)
Partial
Copper Ethernet only declared. Fibre SFP availability to be confirmed at FAT milestone.
IT-3SCADA integration (DNP3 or IEC 61850 over Ethernet)
Meets
IEC 61850 over Ethernet confirmed; DNP3 available as protocol fallback on request.
IT-4On-line DGA monitoring unit (per §9.2 and §7.4)
Not addressed
DGA monitoring unit not declared in scope. Commercial section omits line item — clarification and pricing required.
IT-5Cybersecurity attestation — IEC 62443 / firmware version lock
Not addressed
No cybersecurity certification declared. IEC 62443 attestation and firmware version register required before award.
IT-6ISO/IEC 27001:2022 QMS certification
Not addressed
Not declared. Explicit ISO 27001 or equivalent attestation required at clarification stage.

Documents submitted

1/4 filed
DocumentStatus / detailRef
IEC 61850 SCL / CID configuration fileSubstation Configuration Language file provided; validated against ACME IED library.
ISO/IEC 27001:2022 certificateNot declared.
Firmware version register & SBOMNot submitted. Required per ACME IT Security Procedure IT-SEC-012 before award.
IEC 62443 level attestationNot submitted. Required for embedded OLTC and monitoring controller firmware.
Submission completeness · 100%

All required submission items received.


AI assessment

  • I1.

    Does the on-line monitoring module support IEC 61850 Edition 2.1 reporting?

    Meets

    "Online DGA module with DNP3 / IEC 61850 reporting per Sec. 3.4 of the technical proposal."

    Vendor declares both DNP3 and IEC 61850 — confirms interoperability with ACME SAS replatforming.

  • I2.

    Tap changer position monitoring — analogue, digital, or fibre?

    Partially meets

    "MR VRC-1 vacuum on-load (HV)"

    Conventional analogue monitoring — adequate but not preferred for the new SAS architecture.

  • I3.

    Cybersecurity — IEC 62443 alignment for the embedded controller firmware?

    Not addressed

    ⚠ This item was not addressed in the vendor's submission. Clarification required before any award decision.

    No formal cyber certification declared. Will require explicit IEC 62443 firmware attestation as a clarification.

  • I4.

    Firmware version of monitoring relay and patching commitment?

    Not addressed

    ⚠ This item was not addressed in the vendor's submission. Clarification required before any award decision.

    Firmware revision and 5-year patching cadence are not addressed in the submission. Required as a contractual annex.

Risk summary

  • significantPatching commitment not declared
  • minorSBOM disclosure pending

This pack was drafted by Aria (, temperature 0.10) at the date and time stated above. Every claim contains a verbatim quote and source page reference from the vendor's bid PDF. Items where the source could not be matched to actual PDF content are shown as "Not Addressed" rather than rendered with an inferred citation, in line with ACME P-AI Procedure Sec. 4.

Reviewed by: Eng. Saif Al-Dhaheri · Pending sign-off.

Source viewer
Nexara bid · 38 pagespage 10
Open PDF
Nexara Power SystemsD-TX-2026-0047 · p. 10 of 38
Technical — Protection & Monitoring

[Section excerpt]

Lorem ipsum technical text — IEC 60076-1, IEC 60076-3 references for the offered transformer. Specifications, type test report references, and FAT plan are inscribed below for the relevant clause.

↳ Cited passage (highlighted)

"Online DGA module with DNP3 / IEC 61850 reporting per Sec. 3.4 of the technical proposal."

Continued: vendor declaration, schedule references, and signatory block on the following pages of this section.

tenders@nexarapower.aepage 10 / 38